The S&C Line-Rupter Switch is a group-operated switch that uses three independent sealed-for-life interrupters with integral disconnects. It is exceptionally suited for unique mounting applications, including transmission line tower mounting, existing substation structure mounting, and inverted mounting.

Each pole-unit of a Line-Rupter Switch includes a brain which provides built-in positive sequence control . . . and a fully enclosed stored-energy source dedicated solely to operation of the interrupting unit which is in the circuit at all times. Close-and-trip mechanisms are fully enclosed and protected, too. There are no external linkages, lever arms, cams, shunts, etc. that must be coordinated with a disconnect blade to accomplish circuit interruption. Positively sequenced operation is assured regardless of severe weather conditions such as high winds, rain, sleet or snow.

Line-Rupter Switches are available in three-pole vertical-break style and are intended for upright or vertical mounting on a structure, or upright mounting on S&C Mounting Pedestals, or pedestals furnished by the user. Line-Rupter Switches include a manual operating mechanism with geared operating handle. Alternately, for remote supervisory control, power operation can be provided with an S&C Switch Operator - Type LS-2.

kVAmperes, RMS
Nom.MaxBILCont.Short Time – MomentaryShort Time – 3-Second
115 123 550 1200 61 000 40 000
2000 61 000 40 000
138 145 650 1200 61 000 40 000
2000 61 000 40 000
161 169 750 1200 61 000 40 000
2000 61 000 40 000
230 242 900 1600 61 000 40 000
2000 61 000 40 000


Application Ratings

 ClassQualificationsMaximum Amperes,
Interrupting RMS
Symmetrical
Line Switching Load Splitting (Parallel or Loop Switching) Max 60-Hertz recovery voltage: 150 kV RMS 1200/1600/2000
Load Dropping Circuits with all load-side transformers connected solidly grounded-wye on the primary (Line-Rupter switch) side and delta on the secondary side. 1200/1600/2000
Circuits with load-side transformers connected other than as described above. 1200/1600/2000
Line Dropping  
Cable Switching Load Splitting (Parallel or Loop Switching) Max 60-Hertz recovery voltage: 150 kV RMS 1200/1600/2000
Load Dropping Circuits with all load-side transformers connected solidly grounded-wye on the primary (Line-Rupter switch) side and delta on the secondary side. 1200/1600/2000
Circuits with load-side transformers connected other than as described above. 1200/1600/2000
Cable Dropping Shielded cable 550
Unshielded cable 550

 Depends on continuous current rating on the Line-Rupter switch.
 Maximum length of line: 300 miles

high-speed switch operator for Line-Rupter Switches

Type LS-2 Switch Operator is a high-speed operator especially designed for Line-Rupter Switches. (Maximum operating time of 2.2 seconds.)

The operator features a sturdy welded enclosure with baffled louvers that allow air circulation, but keep out rain. The interior of the weatherproof, dustproof enclosure is accessed by a hinged door . . . rather than removal of the entire enclosure.

The Type LS-2 Switch Operator includes:

  • Eight-pole adjustable auxiliary switch contacts, coupled to the motor
  • External trip and close push buttons with padlockable cover
  • Built-in manual operating handle for the disconnect
  • Decoupling mechanism that allows decoupling and locking of the disconnect in the open position
  • Mechanical position indicator
  • Non-resettable operation counter.


Optional features for the Type LS-2 Switch Operator include:

  • Additional auxiliary-switch contacts
  • LED position indicating lamps
  • Remote-control blocking switch
  • Space-heater thermostat
  • Duplex receptacle with ground-fault circuit interrupter, and convenience light lampholder with switch.
  • Key interlocks